●Small size, low weight and low cost
●ITAR free
●Insensitve to magnetc felds
●0.5°/h gyro bias instability
●0.15°/√h angular random walk
●±400°/s angular rate input range
●10°/h gyro bias error over temperature gradients
●0.05mg accelerometer bias instability
●±10g acceleraton input range (optonal ranges avail.)
●3 inclinometers for accurate levelling
● Auxiliary input
SPECIFICATIONS
Parameter
|
Min
|
Nom
|
Max
|
Unit
|
GENERAL
|
||||
Weight
|
55
|
g
|
||
Operatng temperature
|
-40
|
85
|
°C
|
|
Supply voltage
|
4.5
|
5.0
|
5.5
|
V
|
Supply current
|
300
|
mA
|
||
Start-up tme
|
1
|
s
|
||
Sample rate
|
2000
|
SPS
|
||
Mechanical shock, any directon
|
1500
|
g
|
||
RS422 transmission bit rate
|
1.84
|
Mbit/s
|
||
Misalignment
|
1
|
mrad
|
||
GYRO
|
||||
Input range
|
±400
|
°/s
|
||
Resoluton
|
0.22
|
°/h
|
||
Bias instability
|
0.5
|
°/h
|
||
Angular random walk
|
0.15
|
°/√h
|
||
Bias error over temperature gradients
|
±10 2)
|
°/h rms
|
||
Scale factor accuracy
|
±500
|
ppm
|
||
ACCELEROMETER
|
||||
Input range
|
±10 3)
|
g
|
||
Resoluton
|
1.9
|
µg
|
||
Bias instability
|
0.05
|
mg
|
||
Velocity random walk
|
0.06
|
m/s/√h
|
||
Bias error over temperature gradients
|
±2 2)
|
mg rms
|
||
Scale factor accuracy
|
±300
|
ppm
|
||
INCLINOMETER
|
||||
Input range
|
±1.7
|
g
|
||
Resoluton
|
0.2
|
µg
|
||
Scale factor accuracy
|
±1500
|
ppm
|
1) Optonal ranges are available
2) Conditon: ΔT ≤ 1°C/min
3) Optonal ranges: ±2g, ±5g, ±30g, ±100g