典型性能
宽输入电压范围,单、双路输出
内置输入滤波器
固定开关频率
国际标准封装
长期短路保护,自恢复
参数表
条件 所有参数测试均在标称输入电压、纯阻性额定负载及25℃室温下测得
|
输入特性Input
|
||||
输入电压范围
|
小(Vdc)
|
标称(Vdc)
|
大(Vdc)
|
|
9
|
12
|
18
|
||
18
|
24
|
36
|
||
36
|
48
|
72
|
||
72
|
110
|
144
|
||
遥控端
|
无遥控端
|
|
|
|
输入欠压保护
|
低于低端输入电压保护
|
自恢复
|
|
|
输出特性 Output
|
||||
输出电压精度
|
满载
|
Vo1
|
±1.0%,
|
|
Vo2
|
±3.0%
|
|||
源效应
|
满载
|
Vo1
|
±0.5%
|
|
Vo2
|
±1.5%
|
|||
负载效应
|
20%~100%额定负载
|
Vo1
|
±0.5%
|
|
Vo2
|
±1.5%
|
|||
纹波及噪声(峰-峰)
|
20MHz BW满载
|
Vo≤5V
|
50mVp-p
|
|
其它
|
100mVp-p
|
|||
Vo≥48V
|
200mVp-p
|
|||
动态响应
|
25%的标称负载阶跃
|
|
±3%/200µs
|
|
温度系数
|
|
|
±0.02%/℃
|
|
综合特性 General
|
||||
效率
|
满载,标称电压输入
|
|
84%典型
|
|
隔离耐压
|
|
输入与输出
|
500Vdc
|
|
输入与外壳
|
500Vdc
|
|||
输出与外壳
|
500Vdc
|
|||
110V输入系列
|
输入与输出
|
1500Vdc
|
||
开关频率
|
|
300KHz 典型
|
大330KHz
|
|
工作环境温度
|
自然空气散热
|
|
-25℃~+55℃
|
|
储存温度
|
|
|
-55℃~+105℃
|
|
工作壳温
|
|
|
-25℃~+95℃
|
|
相对湿度
|
|
|
10%~90%
|
|
小无故障间隔时间(MTBF)
|
|
|
2×106h
|
产品列表
产品型号
|
输入电压范围
(Vdc)
|
输出电压/电流(Vdc/A)
|
典型效率
|
|
Vo1
|
Vo2
|
|||
KW12S2V5-20W
|
12V(9-18V)
|
2.5/6
|
/
|
76%
|
KW12S3V3-20W
|
3.3/6
|
/
|
80%
|
|
KW12S05-20W
|
5.05/4
|
/
|
82%
|
|
KW12S12-20W
|
12/1.67
|
/
|
84%
|
|
KW12S15-20W
|
15/1.33
|
/
|
84%
|
|
KW12S24-20W
|
24/0.83
|
/
|
84%
|
|
KW12D05-20W
|
+5.05/+2
|
-5.05/-2
|
82%
|
|
KW12D12-20W
|
+12/+0.83
|
-12/-0.83
|
83%
|
|
KW12D15-20W
|
+15/+0.67
|
-15/-0.67
|
84%
|
|
KW12D05-05-20W
|
+5.05/+3
|
-0.05/-1
|
81%
|
|
KW24S2V5-20W
|
24V(18-36V)
|
2.5/6
|
/
|
76%
|
KW24S3V3-20W
|
3.3/6
|
/
|
80%
|
|
KW24S05-20W
|
5.05/4
|
/
|
82%
|
|
KW24S12-20W
|
12/1.67
|
/
|
84%
|
|
KW24S15-20W
|
15/1.33
|
/
|
84%
|
|
KW24S24-20W
|
24/0.83
|
/
|
84%
|
|
KW24D05-20W
|
+5.05/+2
|
-5.05/-2
|
82%
|
|
KW24D12-20W
|
+12/+0.83
|
-12/-0.83
|
83%
|
|
KW24D15-20W
|
+15/+0.67
|
-15/-0.67
|
84%
|
|
KW24D05-05-20W
|
+5.05/+3
|
-0.05/-1
|
81%
|
|
KW48S2V5-20W
|
48V(36-72V)
|
2.5/6
|
/
|
76%
|
KW48S3V3-20W
|
3.3/6
|
/
|
80%
|
|
KW48S05-20W
|
5.05/4
|
/
|
82%
|
|
KW48S12-20W
|
12/1.67
|
/
|
84%
|
|
KW48S15-20W
|
15/1.33
|
/
|
84%
|
|
KW48S24-20W
|
24/0.83
|
/
|
84%
|
|
KW48D05-20W
|
+5.05/+2
|
-5.05/-2
|
82%
|
|
KW48D12-20W
|
+12/+0.83
|
-12/-0.83
|
83%
|
|
KW48D15-20W
|
+15/+0.67
|
-15/-0.67
|
84%
|
|
KW48D05-05-20W
|
+5.05/+3
|
-0.05/-1
|
81%
|
|
KW110S2V5-20W
|
110V(72-144V)
|
2.5/6
|
/
|
76%
|
KW110S3V3-20W
|
3.3/6
|
/
|
80%
|
|
KW110S05-20W
|
5.05/4
|
/
|
82%
|
|
KW110S12-20W
|
12/1.67
|
/
|
84%
|
|
KW110S15-20W
|
15/1.33
|
/
|
84%
|
|
KW110S24-20W
|
24/0.83
|
/
|
84%
|
|
KW110D05-20W
|
+5.05/+2
|
-5.05/-2
|
82%
|
|
KW110D12-20W
|
+12/+0.83
|
-12/-0.83
|
83%
|
|
KW110D15-20W
|
+15/+0.67
|
-15/-0.67
|
84%
|
|
KW110D05-05-20W
|
+5.05/+3
|
-0.05/-1
|
81%
|
注:1、当环境温度为+50~70℃时,应按降额曲线图使用。