Number of electrical cores |
2 |
2 |
2 |
2 |
|
Design of the shield |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
|
Type of electrical connection FastConnect |
Yes |
Yes |
Yes |
Yes |
|
Core diameter |
|||||
|
0.64 mm |
||||
Outer diameter |
|||||
|
0.65 mm |
0.64 mm |
0.65 mm |
0.65 mm |
|
|
2.55 mm |
2.55 mm |
2.55 mm |
2.55 mm |
|
|
5.4 mm |
5.4 mm |
5.4 mm |
5.4 mm |
|
|
8 mm |
8 mm |
8 mm |
8 mm |
|
Symmetrical tolerance of the outer diameter of cable sheath |
0.4 mm |
0.4 mm |
0.4 mm |
0.4 mm |
|
Material |
|||||
|
PE |
PE |
PE |
PE |
|
|
PVC |
PVC |
PVC |
PVC |
|
|
PVC |
PVC |
PUR (TPE-U) |
PE; Outer cover made of PE is especially suitable for the food processing industry |
|
Color |
|||||
|
red/green |
red/green |
red/green |
red/green |
|
|
Violet |
blue |
Violet |
Black |
|
Bending radius |
|||||
|
37.5 mm |
37.5 mm |
75 mm |
30 mm |
|
|
75 mm |
75 mm |
150 mm |
60 mm |
|
Tensile load maximum |
100 N |
100 N |
100 N |
100 N |
|
Weight per length |
80 kg/km |
80 kg/km |
71 kg/km |
67 kg/km |
|
Permitted ambient conditions |
|||||
Ambient temperature |
|||||
|
-40 ... +75 °C |
-40 ... +75 °C |
-40 ... +60 °C |
-40 ... +60 °C |
|
|
-40 ... +75 °C |
-40 ... +75 °C |
-40 ... +60 °C |
-40 ... +60 °C |
|
|
-40 ... +75 °C |
-40 ... +75 °C |
-40 ... +60 °C |
-40 ... +60 °C |
|
|
-40 ... +75 °C |
-40 ... +75 °C |
-40 ... +60 °C |
-40 ... +60 °C |
|
|
Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 |
Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 |
Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 |
Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 |
|
Burning behavior |
flame resistant according to IEC 60332-3-24 (Category C) and UL 1685 (CSA FT 4) |
flame resistant according to IEC 60332-3-24 (Category C) |
flame resistant according to IEC 60332-1 |
inflammable |
|
Chemical resistance |
|||||
|
oil resistant according to IEC 60811-2-1 (4 hours / 70°C) |
oil resistant according to IEC 60811-2-1 (4 h / 70°C) |
oil resistant according to IEC 60811-2-1 (7x24h/90°C) |
oil resistant according to IEC 60811-2-1 (4 h / 70°C) |
|
|
Conditional resistance |
Conditional resistance |
resistant |
Conditional resistance |
|
|
conditional resistance |
conditional resistance |
conditional resistance |
conditional resistance |
|
Radiological resistance to UV radiation |
resistant |
resistant |