产品简介:
能够测量60KV/30KV 的高压探头
HV-P60
HV-P60 |
Specifications |
Maximum input voltage |
DC 60 kV or AC peak*
Single-shot pulse of 80 kV, standard pulse wave |
Bandwidth |
DC to 50 MHz, within -3 dB |
Rise time |
7 ns or less (for probes only) |
Input RC |
1000 MW ±5% //5 pF ±2 pF |
Attenuation |
2000:1 ±5% |
Cable length |
Approx. 4 m |
Connector |
BNC type |
Used for |
Oscilloscope with input RC: 1 MW, 15 to 50 pF |
Size |
Approx. 88 mm (ø) x 338 mm (L) |
Weight |
Approx. 3.5 kg (including accessories) |
Accessories |
Matching box, clamp, probe tip, ground lead, adjusting screwdriver, accessory bag |
Options |
High-voltage probe stand SK-301 (produced upon order)
The SK-301 can be used with both the HV-P60 and the HV-P30. It is attached by turning the probe bracket upside down (for HV-P60/HV-P30). |
* The P-P voltage drops if the CW is 100 kHz or greater.
|
|
This is a passive probe that measures high-voltage waveforms by connecting to an oscilloscope, and has the following characteristics: the bandwidth is DC to 50 MHz, the maximum input is DC 60 kV, and the attenuation is 2000:1. |
Characteristic curve |
|
Maximum Input Voltage and Frequency (Sine Wave) [HV-P60]
|
HV-P30
HV-P30
High-voltage probe stand SK-301 (sold separately) |
Specifications |
Maximum input voltage |
DC 30 kV or DC + AC peak*
Single-shot pulse of 40 kV, repetitive signal |
Bandwidth |
DC to 50 MHz, within -3dB |
Rise time |
7 ns or less (for probes only) |
Input RC |
100 MW ±5% //7 pF or less |
Attenuation |
1000:1 ±5% |
Cable length |
Approx. 3 m |
Connector |
BNC type |
Used for |
Oscilloscope with input RC: 1 MW, 15 to 50 pF |
Size |
Approx. 66 mm (ø) x 315 mm (L) |
Weight |
Approx. 3 kg (including accessories) |
Accessories |
Matching box, clamp, probe tip, ground lead, adjusting screwdriver, accessory bag |
Options |
High-voltage probe stand SK-301 (produced upon order)
The SK-301 can be used with both the HV-P60 and the HV-P30. It is attached by turning the probe bracket upside down (for HV-P60/HV-P30). |
* The P-P voltage drops if the CW is 100 kHz or greater.
|
|